- Hct should be between 10-65. Testing Limitations using the INFORM II.
The Accu-Chek Inform II test strip is the only diabetic test strip designed with patented dual alternating and direct ACDC current technology that tests a wider range of variables compared to other blood glucose testing systems.
Accu chek inform ii. Accu-Chek Inform II is a user-friendly hand-held system for point-of-care glucose testing and monitoring in hospitals. You appear to be using incognitoprivate browsing mode or an ad blocker which may adversely affect your experience on the site. The Accu-Chek Inform II system is designed to deliver data with speed and efficiency helping you provide optimal care.
Wireless meter quickly transfers data. The Accu-Chek Inform II system is the first point-of-care blood glucose device to offer truly wireless technology at. ACCU-CHEK Inform II test strips have been developed such that there is NO interference due to Maltose.
Patient hematocrit should be between 10-65 Lipemic samples triglycerides in excess of 1800 mgdl may produce elevated results Blood concentrations of galactose 15 mgdl will cause overestimation of blood glucose results. Manual versions 1 2 3 and 3x are for Accu-Chek Inform II meters with serial number versions UU13000000 to less than UU14000000. Manual versions 4 5 6 and 7x are for Accu-Chek Inform II meters with serial number versions greater than or equal to UU14000000.
Manual version Revision date Changes Version 10 2012-10 New document. Accu-Chek Inform II Base Unit The Accu-Chek Inform II Base Unit with new hard-ware and software REF 07671717190 has replaced the legacy version REF 05060290001 in this manual. An overview of the legacy Accu-Chek Inform II Base Unit and technical information have been moved to Appendix F.
2 0 8818703001 02 2019-03 EN-CAN Accu-Chek Inform II Supplement to the Operators Manual Version 6 Revision History Purpose of document This document provides a description of changes to the Operators Manual V6 for SW 040300. This supplement is valid for and intended to be used in conjunction with the Accu-Chek Inform II Operators. Roche Accu-Chek inform II Operator Training Video.
ACCU-CHEK INFORM II CONTROLS US 10CS Version 13 Revision Date 09-18-2014 Print Date 12-06-2014 5 10 SECTION 11. TOXICOLOGICAL INFORMATION Ctrl 1Ctrl 2 Information on likely routes of exposure Acute toxicity Not classified based on available information. Acute oral toxicity.
Acute toxicity estimate. ACCU-CHEK Inform II Training Competency 92018 Infection Control Requirements Perform Hand Hygiene before and after wearing gloves. Always wear a new pair of clean gloves for each patient.
Use appropriate PPE when performing testing on isolation patients. Kontrolllösung Durchführung QC-Test Glukosekontrolltest Anleitung - Anwendung. Wie kann ich mit einem Blutzu.
Accu-Chek Inform II meter base and power supply. Store between 5C and 40C and 10-85 humidity. Accu-Chek Inform II Test Strips.
Store strips between 4C and 30C 39F - 86F and 10-80 humidity. Use strips at temperatures between 16C and 35C 61F - 95F and between 10-80 relative humidity. Cleaning the Accu-Chek Inform II meter after each patient use.
A prevents transmitting contamination from one patient to another. B is a CMS standard. C is a College of American Pathologists CAP standard.
D must be performed using hospital approved wipes. 042013 Glucose Whole Blood Accu-Chek Inform II 7 NOTE. New lot numbers are entered by the POCT department Data will upload when the meter is docked.
Accu-Chek Inform II Test Strips. Test strips expire at manufacturers date on bottle Document Opened Date on vial Do NOT insert a test strip until prompted by the meter. 2 0 5956200001 07 2021-05 EN-CAN ACCU-CHEK Inform II Operators Manual Version 71 Revision History Manual content version Revision date Changes Version 10 2008-01 New document international launch with document 0 4807839001 01 EN 2008-01.
Version 20 2009-08 Update new SW version 0200. Testing Limitations using the INFORM II. - Hct should be between 10-65.
- lipemia samples triglycerides in excess of 1800 mgdL may produce elevated results. - blood concentrations of galactose 15 mgdL will cause overestimation of blood glucose results. - Intravenous admin of ascorbic acid which results in blood concentrations of ascorbic.
Accu-Chek Inform II Base Unit serial number ready to help assist our customer care group in troubleshooting. Note on the use of base unit in this manual Note on illustrations in this manual Unless otherwise specified the term base unit refers to both the Accu-Chek Inform II Base Unit and the Accu-Chek Inform II Base Unit Light. Accu-Chek Inform II Base Unit The Accu-Chek Inform II Base Unit with new hard-ware and software REF 07671717190 has replaced the legacy version REF 05060290001 in this manual.
An overview of the legacy Accu-Chek Inform II Base Unit and technical information have been moved to Appendix E. The ACCU-CHEK Inform II helps make glucose testing easy and fast. Patient and control tests are automatically uploaded to the facilitys computer system.
The wireless feature eliminates the need to dock the meter to send or receive information from the computer system. Although not needed to download results you will still have a wired. The Accu-Chek Inform II test strip is the only diabetic test strip designed with patented dual alternating and direct ACDC current technology that tests a wider range of variables compared to other blood glucose testing systems.
Exclusive ACDC technology allows more than 150 integrity checks which includes accurate and efficient. ACCU-CHEK Inform II Glucose Meter Meter Cleaning Effective Date. April 25 2017 Version.
13 Printed versions of this document without document owner authorization are UNCONTROLLED Page 1 of 3 ACCU-CHEK Inform II Glucose Meter Meter Cleaning and Disinfection Step Detail 1. Perform hand hygiene and don gloves. POCT Glucose Accu-Chek Inform II Quiz CUsersakeenanDownloadsGlucose Accu-Chek Inform II Quiz 2017 docx Retain documentation in employee department file Page 1 of 3 1.
When a new lot of control solution or test strips are received the new lot number is uploaded into the meter by the POCT department. N-Acetylcysteine Interference with Accu-Chek Inform II Blood Glucose - Providers v10 08-16-21 Page 2 of 2 Discontinue Existing and Enter New Orders Step Action 1 Click the OK button in the displayed Discern window. There may be more than one Accu -Chek or.