Accu-Chek Inform II BLOOD GLUCOSE MONITORING SYSTEM Operators Manual. ACCU-CHEK Inform II Glucose Meter Meter Cleaning Effective Date.
If using simulated patient.
Accu chek inform ii system. Accu-Chek Inform II is a user-friendly hand-held system for point-of-care glucose testing and monitoring in hospitals. You appear to be using incognitoprivate browsing mode or an ad blocker which may adversely affect your experience on the site. The Accu-Chek Inform II system is designed to deliver data with speed and efficiency helping you provide optimal care.
Wireless meter quickly transfers data. The Accu-Chek Inform II system is the first point-of-care blood glucose device to offer truly wireless. HI on the ACCU-CHEK Inform II system display indicates that the blood glucose value is over mgdL and the result may be the reading range of the meter.
On the vial or bottle labels or in the meter 16. The ACCU-CHEK Inform II System Operators Manual 17. Accu-Chek Inform II Base Unit The Accu-Chek Inform II Base Unit with new hard-ware and software REF 07671717190 has replaced the legacy version REF 05060290001 in this manual.
An overview of the legacy Accu-Chek Inform II Base Unit and technical information have been moved to Appendix F. Accu-Chek Inform II BLOOD GLUCOSE MONITORING SYSTEM Operators Manual. 2 0 5956200001 07 2021-05 EN-CAN ACCU-CHEK Inform II Operators Manual Version 71 Revision History Manual content version Revision date Changes Version 10 2008-01 New document international launch with document 0.
ACCU-CHEK Inform II test strips have been developed such that there is NO interference due to Maltose. Patient hematocrit should be between 10-65 Lipemic samples triglycerides in excess of 1800 mgdl may produce elevated results Blood concentrations of galactose 15 mgdl will cause overestimation of blood glucose results. Accu-Chek inform II Blood Glucose Monitoring System is intended for testing outside the body in vitro diagnostic use and is intended for multiple-patient use in professional healthcare settings.
This system should only be use with single-use auto-disabling lancing devices. ACCU-CHEK Inform II Test Strip The ACCU-CHEK Inform II test strip contains six gold electrodes see Figure 2 that allow the system along with its patented technology to perform extensive quality checks. The two principle measurement electrodes the counter electrode and working electrode conduct integrity checks prior to measuring.
Accu-Chek Inform II is a user-friendly hand-held system for point-of-care glucose testing and monitoring in hospitals. Det verkar som att du använder inkognito modeprivat surfningsläge eller en annonsblockerare vilket kan försämra din upplevelse på webbplatsen. For all questions about the Accu-Chek Inform II system that are not answered in this manual contact your Roche representative see Chapter 12.
In order to expedite troubleshooting please have ready your Accu-Chek Inform II meter its serial number this manual and all related consumables when you call. If you suspect a com-. ACCU-CHEK Inform II Training Competency 92018 RechargerDownloader Base Unit Design Battery charging contacts Infrared communication for the meter The meter should always be in a base unit when not testing patients so that battery stays charged.
Some base units download results and. Roche Accu-Chek inform II Operator Training Video. Accu-Chek Inform II.
To data management system. Bring meter to patient finger and apply 2nd drop of blood to the front edge of test strip. Meter beeps when sufficient sample detected.
If using simulated patient. The AccuChek Inform II system complies with the requirements of EN ISO 151972013 In vitro diagnostic test systems Requirements for blood glucose monitoring systems for selftesting in managing diabetes mellitusa a The system also complies with. The ACCU-CHEK Inform II system quantitatively measures glucose in whole blood.
The enzyme on the test strip mutant variant of quinoprotein glucose dehydrogenase from Acinetobacter calcoaceticus recombinant in E. Coli converts the glucose in the blood sample to gluconolactone. This reaction creates a harmless electrical DC current that the.
ACCU-CHEK Inform II Glucose Meter Meter Cleaning Effective Date. April 25 2017 Version. 13 Printed versions of this document without document owner authorization are UNCONTROLLED Page 1 of 3 ACCU-CHEK Inform II Glucose Meter Meter Cleaning and Disinfection Step Detail 1.
Perform hand hygiene and don gloves. Accu-Chek Inform II System from Roche. Professional connected blood glucose meter with wireless RF functionality to test the right patient at the right time.
The Roche Accu-Chek Inform II System is user-friendly hand-held system for Point of Care glucose testing and monitoring in hospitals. Cleaning the Accu-Chek Inform II meter after each patient use. A prevents transmitting contamination from one patient to another.
B is a CMS standard. C is a College of American Pathologists CAP standard. D must be performed using hospital approved wipes.
The ACCU-CHEK Inform II helps make glucose testing easy and fast. Patient and control tests are automatically uploaded to the facilitys computer system. The wireless feature eliminates the need to dock the meter to send or receive information from the computer system.
Accu-Chek Inform II Base Unit The Accu-Chek Inform II Base Unit with new hard-ware and software REF 07671717190 has replaced the legacy version REF 05060290001 in this manual. An overview of the legacy Accu-Chek Inform II Base Unit and technical information have been moved to Appendix E. Accu-Chek Inform II System Glucose Meter Training Competency Name Title print.
Demonstrate cleaning procedure state cleaning required after every patient test wearing gloves wipe Accu - Chek Inform Meter with Clorox Germicidal wipes. Refer to POC Devices CleaningDisinfecting Guide for. Accu-Chek Inform II meter base and power supply.
Store between 5C and 40C and 10-85 humidity. Accu-Chek Inform II Test Strips. Store strips between 4C and 30C 39F - 86F and 10-80 humidity.
Use strips at temperatures between 16C and 35C 61F - 95F and between 10-80 relative humidity.