What You Really Need. Standpipe High-rise Packs - Part 1.
Modified FDNY High Rise Load.
High rise pack loads. Standpipe High-rise Packs - Part 1. Preparation before an emergency is commonplace to us in the fire service. For fires in standpipe-equipped buildings this statement couldnt be truer.
We have a similar load that we use for our high rise packs. Our loads are 150 of 1 34 line with a fog nozzle. Along with that the pack had a gated wye attached to it already to make the standpipe.
Modified FDNY High Rise Load. Over the past 2 years my department has re-evaluated our high-rise setups. In doing such we moved away from carrying 50 of 25 hose a gate-wye and 100 of 175 hose to carrying 4 bundles of 2 hose.
Because we changed the hose configuration we also re-evaluated how we bundled it. Modified version of a Cleveland load to use off standpipe connection. Charges into an easily deployable coil while connecting on the floor below the fire f.
The picture is of a hi-rise pack with the butts ending on the top of the load not in the middle as shown in the FDNY SOPs. I have used and liked the style of load in the photograph. If the left strap was moved slightly inward the sections can be set down and coupled while still bundled together.
Modified FDNY High Rise Load. Over the past 2 years my department has re-evaluated our high-rise setups. In doing such we moved away from carrying 50 of 25 hose a gate-wye and 100 of 175 hose to carrying 4 bundles of 2 hose.
High-Rise Hose Packs. What You Really Need. Matt Stuckey explains why dependence on a single hosenozzle combination for all high-rise fires is dangerous business.
User-friendly high-rise standpipe hosepacks. Specifically a high-rise standpipe hosepack should be. Easy and comfortable to carry.
Easy and quick to deploy. The high-rise standpipe hosepack used by the Denver Fire Department DFD the Denver Hosepack meets all of those criteria. Types of High-Rise Buildings Structural Systems.
Braced frame structural system. Braced frames are cantilevered vertical trusses resisting laterals loads primarily diagonal members that together with the girders form the web of the vertical truss with the columns acting as the chords. A hose pack that allows one person to carry up to 150 ft.
Of 2 hose with nozzle and adapters for standard pipe hook-ups. This high-rise hose pack can also be used for wild land fires. Made of 1000 denier Cordura nylon with web carrying handles and shoulder strap for use as a back pack.
DFR HighRise Hose Packs. If playback doesnt begin shortly try restarting your device. High Rise Carry Pack.
The HP-300 High Rise Hose Carry Pack holds 150 feet of 1-34 double jacket hose with nozzle adapters gated wye with room for spanners and door stops. Soft bottom covered with extra layer of MagnaTuff material. Made from 18 oz.
The goal is to keep the weight light and dividable among the men. As always I recommend 50 foot packs. If you must use a house pack for both do not go more than 100 feet in the pack whether 1 ¾- 2 or 2 ½-inch lines.
As mentioned earlier 150 feet of 1 ¾-inch with a 2 ½-. Firefighter High Rise Packs for Sale. At All Hands Fire Equipment we have a great selection of firefighter high rise packs for sale.
Our company proudly supplies Fire Departments with high-quality and reliable high-rise packs. The Highrise Hotel Apartment Pack is designed to carry accordion fold or circle style hose loads although many other types of loads can be carried. The Highrise Hotel Apartment Pack is 36 long and holds hose bundles from 44 to 58 long.
The Highrise Hotel Apartment Pack can be carried over the shoulder under the arm or draped over an air pack bottle. Learn more about NFFF 911 Memorial Stair Climbs around the country. Gustin Pack 100 Hose Bundle.
The Gustin Pack is a 100 Feet of 175 with a 78 smoothbore to extend a line preconnect that comes up short or beyond the preconnect off a static 25 or to extending a preconnected 25. Can be connected to a playpipe break apart wye waterthief or what you have to feed it the proper amount. The Nozzle Forward Vado Canis Vado.
In a high rise the weight of the structure dead load should higher than the weight of material live load that it will support. In fact the structural weight in lower levels of high rise should be much higher than material weight but this is not always visible to naked eye. The High Rise Hose Pack can be unloaded parachute-like producing a reliable supply of water.
The end result is a simple safe and efficient hose evolution. Pro Bags manufactures the High Rise Hose Pack for PAL Pack and has the exclusive distribution rights for this. To solve these problems we have developed a second pack designed to cover the distance between the water supply and the coiled hose.
When the two packs are used together the distance between the fire and supply can be covered in either a forward or reverse direction depending on the job and hose deployed into a coil from the Attack Pack can. 2 inch hose high-rise pack untenable tenable deployment About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy Safety How YouTube works Test new features 2021.